Technical knowledge base
An engineering reference
for production decisions.
Key comparisons and technical answers on material selection, tool preparation and in-process measurement.
Tool measurement methods
| Criterion | Laser measurement | Contact measurement |
|---|---|---|
| Measuring principle | Non-contact beam interruption | The tool touches a measuring surface |
| Application focus | Rotating tools, small cutters and suitable geometry | Length and diameter checks on suitable tool geometry |
| Points to check | Optical cleanliness, coolant and chip management | Contact direction, force and cleanliness of the measuring surface |
| Common requirement | Calibration, machine and controller compatibility, and a verified measuring cycle | |
The table explains the selection approach. Model-specific technical values and compatibility must be verified with the manufacturer's documentation.
Technical questions and answers
01Why are tool holder, balancing and probe selection critical when machining titanium and Inconel?
The tool holder and balance support stability during cutting. Probing systems help check the part datum and tool geometry. They should be selected together, based on the material, tool overhang, spindle speed, machine interface and critical tolerances.
02What is the difference between a laser tool setter and a contact tool setter?
Laser systems measure without touching the tool; they can be considered for checking rotating tools and small cutters. With contact systems the tool touches a measuring surface. The choice depends on tool diameter, geometry, coolant, cleanliness and machine compatibility.
03How do HAIMER shrink fit and balancing technology support the spindle?
A shrink fit holder grips a suitable tool shank by thermal clamping. Balancing the tool and holder assembly helps reduce unbalance forces and vibration at high speed. This approach helps keep spindle loads under control; any gain in service life depends on the application conditions.
04Does sub-micron repeatability mean the part will be machined to the same accuracy?
No. The 0.35 µm (2σ) stated for the Renishaw RMP24-micro is the probe repeatability under manufacturer test conditions. The total measurement uncertainty of the part is also affected by the machine, temperature, fixturing, calibration, stylus and measurement strategy.
05What information is needed to order medical titanium?
The alloy grade, product form, dimensions, quantity, the relevant technical standard and the documentation requirement should be stated. Grade 2, Grade 5 and ELI options are evaluated according to the application. Batch traceability and compliance are checked through the delivery documents.
06Which sectors does Inometri provide engineering solutions for?
Inometri focuses on aerospace, space, medical, industrial and automotive, and mould and machine building. It matches precision metrology and probing systems, HAIMER tooling technology and advanced alloy supply to the production needs of these sectors.